Oppolzer - Informatik / Blog


Blog-Hauptseite      Neuester Artikel      Älterer Artikel      Neuerer Artikel      Älterer gleiche Kategorie      Neuerer gleiche Kategorie

ASSEMBLER-L - Fehlender CC=2 als Ergebnis von TRTE

Subject:

Re: missing functionality in TRTE

From:

Bernd Oppolzer <bernd.oppolzer@T-ONLINE.DE>

Reply-To:

IBM Mainframe Assembler List <ASSEMBLER-LIST@LISTSERV.UGA.EDU>

Date:

2013.10.20 22:54:15


With TRT, there was no easy way to test the remaining length; it first had to be
computed by subtracting R1 from the end address.

But with TRTE, the remaining length is in R1+1, so that makes a difference IMHO.

Kind regards

Bernd



Am 20.10.2013 22:44, schrieb E.J.:
> On 10/20/2013 7:07 AM, M.T. wrote:
>> Does anyone have insights (or ideas) why CC 2 (xH) was omitted from
>> TRTE.
>>
>> It is there in TRT and it does come handy when determine if there is a
>> remainder to process after the special-char was found.
>
> I don't think I've ever truly leveraged RC=2 from TRT. I usually test
> the length remaining at the top of the loop via DOEXIT.
>
> --
> E.J
>

Blog-Hauptseite      Neuester Artikel      Älterer Artikel      Neuerer Artikel      Älterer gleiche Kategorie      Neuerer gleiche Kategorie